DSC-A01(B01)+SL70B Brain stereo locator Syringe Pump
Stroke length:70mm
Flow rates:0.96pL/min~506.55uL/min
Syringe:1
Display:High-definition touch screen
Control:Touch Panel / External control signal
Linear Force:>25N
- Product Specifications
- Help
- Service Guarantee
- Related Products
-
Working Mode DSC-A01+SL70B: Injection ; DSC-B01+SL70B: Infusion / Withdraw No. of Syringes 1 Reference flow rates 0.96 pL/min - 506.55 mL/min Syringe Specification 0.5 uL to 250 uL Syringe Selection The syringe can be selected in the manufacturer table, or input the inner diameter of the syringe barrel directly. Max. Stroke length 70 mm Linear speed 0.12 um/min - 121.92 mm/min Steping resolution 0.19 um/ustep Precision Repeat precision 0.05% Linear Force >90N (The appropriate thrust can be set according to the syringe specification) Display 800*400 5-inch high-definition touch screen Power Supply AC 90-264V 50Hz/60Hz Working environment Temperature 0-40℃ Humidity 20%-80% RH no dewing Dimensions Controller: 240mm*149mm*87.5mm; Executive unit: 163mm*34mm*34mm IP rating IP31 Speed adustment on line Current flow rate is adjustable during operation Communication control RS485 / USB optional, touch setting address and baud rate Status output Output start / stop and direction status External control start/stop External control level signal (5-24v) or contact signal to realize start / stop Prompt function Real-time display of the Max / Min flow rate;display of running parameters dynamically Reminder function Sound alarm when run to the target liquid volume Calibration Syringe calibration is available and can store calibration parameters.
Syringe
Syringe ID(mm)
Reference flow rates(pl/min~ul/min)
0.5ul
0.103
0.96~0.96
1ul
0.146
2.15~2.15
2ul
0.206
3.83~3.83
5ul
0.343
11.73~11.73
10ul
0.485
23.94~23.94
25ul
0.729
61.28~61.28
50ul
1.03
115.86~115.86
100ul
1.457
245.13~245.13
250ul
2.304
506.55~506.55
-
How to select the type
Issues to be confirmed before type selection:
1. Determine the required flow rate (mL/min) and the number of channels required;
2. Determine use scenarios; Can be applied directly or used with equipment, supporting control via RS485 or external signals
3. parameter display; The digital tube only displays the rotational speed; LCD display of flow rate, rotational speed and other calibration parameters; The touchscreen displays flow, rpm, and other programmed or configured parameters
4. Liquid composition; Influence hose selection, platinum sulfide silica tubing is recommended for conventional fluids, and inlet hose is recommended for corrosive fluids
About drives
Flow - The higher the drive rpm, the greater the flow, selecting the appropriate driver by reference flow
Control mode - fixed speed; Adjustable speed; Speed adjustable, supporting flow correction (to achieve precise control of flow); Speed adjustable, support flow distribution (quantitative distribution); Multiple forms such as external signal control are available
Parameter display - digital tube, liquid-crystal display, touchscreen
Degree of protection - Requirements for the drive to be sealed, dustproof, and waterproof, depending on the environment of use
About Tubing
Platinum Vulcanized Silicon Rubber Tube – suitable for the transport of most conventional fluids
FWG60/FG60/A-60-F - Food grade, long life
IG60/A-60-G - Industrial grade, long life
PG60/pharmed BPT - Medical grade, long life
Chemical - Resistance to strong corrosive liquids, lined with Teflon coating
KG60/Viton - Strong corrosive resistant liquid, pure Teflon material
-
About the lead time
Peristaltic pump, injection pump, miniature piston pump, domestic silicon rubber tube and other series of products, most of which are off the shelf and can be shipped within 48 hours;
The filling machines, filling systems and other products are usually made to order, with relatively little inventory, a lead time of about 1 – 2 weeks, and a small number of off the shelf items;
Common models of imported hose series products are in stock; Due to the impact of international logistics on the imported hose, the lead time is about 1~4 weeks in special cases;
Remark: All peristaltic pump series products require 3 days of non-stop operation and aging before leaving the factory, to ensure a lower failure rate for customers to rest assured of use
About aftermarket
One year warranty (except consumables, improper use or man-made damage not covered by warranty)
Under special circumstances such as flow differences, service environment, personal reasons due to type selection or actual application, without affecting secondary sales, customer service exchanges may be contacted directly
About Logistics
In China, default Deppong/SF distribution, please communicate with customer service for special requirements and confirm
-
DSC-B01/W150-B01 Microfluidic Syringe Pump
Working Mode Infusion, Withdraw, Infusion / Withdraw, Withdraw / In
DSC-B01+W110B Miniflow Syringe Pump
Working Mode Infusion, Withdraw, Infusion / Withdraw, Withdraw / In
DSC-D02+2xW70B Dual channel independent control Syringe Pump
Working Mode Independent, Reciprocating, Synchronizing, Synchronous
DSC-A01(B01)+W70B Single channel split
Working Mode DSC-A01+W70B: Injection ; DSC-B01+W70B: Infusion / Wit
DSC-D02+2*SL70B Biological experiment Syringe Pump
Working Mode Independent, Reciprocating, Synchronizing, Synchronous
DSC-D04+4*SL70B Four channel independent control Syringe Pump
Working Mode Infusion, Withdraw, Infusion / Withdraw, Withdraw / In